Contents
Academy · Checklists · PRISMA 2020 checklist
PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance
PRISMA 2020 is the current 27-item standard for reporting a completed systematic review, replacing PRISMA 2009. It covers the whole report — not just the study-selection flow diagram many authors treat as sufficient on its own.
PRISMA stands for Preferred Reporting Items for Systematic Reviews and Meta-Analyses. PRISMA 2020, led by Matthew Page and David Moher with 25 co-authors, was published simultaneously in five journals in 2021, updating PRISMA 2009 to reflect methodological advances — risk of bias, certainty of evidence, reporting bias, and automation — since then.
What it is
Page MJ, McKenzie JE, Bossuyt PM, et al. “The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.” BMJ 2021;372:n71; also PLoS Medicine 2021;18(3):e1003583. Open access.
Systematic reviews and meta-analyses inform clinical and policy decisions, so unclear reporting of search strategy, selection, bias assessment or synthesis directly undermines a reader’s ability to judge the conclusions. PRISMA 2020 updates 2009 to cover newer concerns — reporting bias, certainty assessment, automation tools — and to make the checklist clearer to apply.
Systematic reviews, with or without meta-analysis, synthesising trials, observational studies, diagnostic accuracy studies or other evidence types. A separate “PRISMA 2020 for Abstracts” checklist covers the abstract specifically.
Is this the right tool?
Use it when
Authors conducting and writing a systematic review or meta-analysis, from protocol/registration through submission. Many journals require a completed checklist with page numbers at submission. Review teams can also use it at the planning stage alongside PRISMA-P, the protocol-specific extension.
Not the right tool when
A narrative (non-systematic) review with no reproducible search strategy should not claim PRISMA compliance. A protocol written before the review is conducted should use PRISMA-P. Network meta-analyses should add PRISMA-NMA; scoping reviews should use PRISMA-ScR instead of the core checklist, since several core items assume an appraisal-and-synthesis design scoping reviews do not perform.
The checklist
27 items under six section headers.
Title, abstract, introduction
| Item | What it requires |
|---|---|
| 1. Title | Identify the report as a systematic review. |
| 2. Abstract | A structured summary of objectives, methods, results, limitations and funding. |
| 3–4. Rationale and objectives | Context relative to existing knowledge; the review’s questions or aims. |
Methods (1 of 2)
| Item | What it requires |
|---|---|
| 5. Eligibility criteria | Inclusion/exclusion criteria and how studies were grouped for synthesis. |
| 6–7. Information sources and search strategy | All databases/registers searched with last-search dates; the full search strategy for at least one database. |
| 8–9. Selection and data collection | Screening process and reviewer count; extraction methods and verification. |
| 10–11. Data items and risk of bias | Outcome/variable definitions and missing-data assumptions; risk-of-bias method and reviewer count. |
Methods (2 of 2)
| Item | What it requires |
|---|---|
| 12–13. Effect measures and synthesis methods | Effect measure per outcome; how studies were grouped, tabulated, synthesised, software used, heterogeneity explored. |
| 14–15. Reporting bias and certainty | Methods to assess bias from missing results; methods to assess certainty of evidence per outcome. |
Results
| Item | What it requires |
|---|---|
| 16. Study selection | Records screened/assessed/included with exclusion reasons, ideally a flow diagram. |
| 17–18. Study characteristics and risk of bias | Each included study cited and characterised; risk-of-bias results per study. |
| 19–20. Individual and synthesis results | Summary statistics/effect estimates per study, ideally a forest plot; synthesis characteristics, heterogeneity, sensitivity analyses. |
| 21–22. Reporting bias and certainty results | Results of missing-results bias assessment; certainty of evidence per outcome. |
Discussion and other information
| Item | What it requires |
|---|---|
| 23. Discussion | Interpretation against other evidence, limitations of studies and of the review process, implications. |
| 24–27. Registration, support, interests, availability | Registration/protocol access and amendments; funding role; competing interests; availability of data, code and materials. |
Applying it, with the evidence
A 2025 study directly compared systematic reviews that declared PRISMA 2020 use against ones that did not, and found declaring use was not enough: even among reviews that cited PRISMA 2020, no review satisfied every item, overall adherence was 72.8% against 68.4% for non-adopters, and simply attaching the completed checklist file (done by only 9 of 31 adopting papers) was the one behaviour that reliably improved reporting, raising data-availability reporting from 36% to 89%. The authors’ own conclusion: “declaring the use of PRISMA 2020 is insufficient, and researchers must strictly adhere to each item.”
PRISMA 2020 is the default reporting standard for systematic reviews and meta-analyses across nearly all of clinical and health research — Cochrane and non-Cochrane intervention reviews, emergency medicine, oncology, and any field publishing evidence syntheses for guideline development. Most journals now require the completed checklist as a mandatory supplementary file.
In order
Where it goes right
With it — no verifiable example found
Our research for this page did not turn up a named, checkable published paper that explicitly credits this checklist for a well-reported study. Rather than invent one, we are saying so. If you know of one, the EQUATOR Network page for this guideline is the place such examples tend to get collected.
Common mistakes
- Search-strategy reporting (item 7) is the most frequently cited gap. Report the full strategy for at least one database verbatim, not a paraphrase.
- The flow diagram is sometimes shown without exclusion reasons at each stage. Item 16 requires the reasons, not just the counts.
- Certainty-of-evidence assessment is still commonly omitted. A structured approach such as GRADE, reported per items 15/22, closes this gap.
Where it falls short
Without full adherence — Suda et al. 2025, 131 systematic reviews
Of 695 screened emergency-medicine systematic reviews, 31 declared PRISMA 2020 use and 100 did not; both groups were scored against the full 41-sub-item checklist. Adherence was 72.8% (925/1270 applicable items) among declarers versus 68.4% among non-declarers — a real but modest gap, and no review in either group satisfied every item. Weak spots even among declarers: certainty assessment (48%), handling of excluded studies (42%), protocol access (32%); funding disclosure in the abstract was reported by 0% of articles in both groups.
Suda C, Yamamoto N, Tsuge T, et al. “Enhancing Reporting Quality Using the Preferred Reporting Items for Systematic Review and Meta-Analysis 2020 in Systematic Reviews of Emergency Medicine Journals: A Cross-Sectional Study.” Cureus, 2025;17(1):e78255. PMC11871967.
Common questions
Yes — it applies to systematic reviews generally; synthesis items are reported where applicable.
PRISMA 2020 reports the completed review; PRISMA-P reports the protocol, before the review is conducted.
No — use PRISMA-ScR, the dedicated scoping-review extension, since several core items assume appraisal and synthesis a scoping review does not do.
References and sources
- Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 2021;372:n71. read 8 October 2026. doi.org/10.1136/bmj.n71
- EQUATOR Network / PRISMA statement. Official checklist. read 8 October 2026. prisma-statement.org
Each source carries the date it was last read. Where a standard moves, this article is revised rather than left up with a note.
How to cite this article
Pick your referencing style and copy it. Your university or target journal may vary the punctuation — check its guide if it has one.
Pubrica Academy. (2026, October 8). PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance. Pubrica. https://pubrica.com/insights/checklist/prisma-2020-reporting-checklist/
Pubrica Academy. “PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance.” Pubrica, 8 Oct. 2026, pubrica.com/insights/checklist/prisma-2020-reporting-checklist/.
Pubrica Academy (2026) PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance. Pubrica. Available at: https://pubrica.com/insights/checklist/prisma-2020-reporting-checklist/ (Accessed: 15 October 2026).
Pubrica Academy. “PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance.” Pubrica. October 8, 2026. https://pubrica.com/insights/checklist/prisma-2020-reporting-checklist/
Pubrica Academy, ‘PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance’ (Pubrica, 8 October 2026) <https://pubrica.com/insights/checklist/prisma-2020-reporting-checklist/> accessed 15 October 2026.
Pubrica Academy. PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance. [Internet]. Pubrica; 2026 Oct 8 [cited 2026 Oct 15]. Available from: https://pubrica.com/insights/checklist/prisma-2020-reporting-checklist/
Pubrica Academy, “PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance,” Pubrica, Oct. 8, 2026. [Online]. Available: https://pubrica.com/insights/checklist/prisma-2020-reporting-checklist/
@misc{prisma_2020_reporting_checklist_2026,
author = {{Pubrica Academy}},
title = {PRISMA 2020 Has 27 Items, and the Flow Diagram Alone Is Not Compliance},
howpublished = {Pubrica},
year = {2026},
month = {oct},
url = {https://pubrica.com/insights/checklist/prisma-2020-reporting-checklist/},
note = {Accessed: <span data-cite-acc="iso">2026-10-15</span>}
}This article is written to be learned from. Cite it if you are referring to what it says; if you are using the evidence behind it, cite the sources listed above instead.
Pubrica AcademyWritten and maintained by the subject matter experts of Pubrica who do this work. Articles are revised when the standard underneath them moves, and each one carries the date it was last checked.
How Pubrica helps
Pubrica’s evidence-synthesis team builds the search log, flow diagram and risk-of-bias documentation as the review runs, so PRISMA 2020 compliance is assembled alongside the review, not reconstructed at submission.