IVD Performance Evaluation

Performance Evaluation Report Writing for IVD Manufacturers

Pubrica writes IVDR performance evaluation reports for in vitro diagnostic manufacturers. Our IVD performance evaluation writers prepare performance evaluation plans and reports under IVDR Annex XIII, with scientific validity, analytical performance and clinical performance each built on its own evidence. Keeping the three separate gives the Notified Body a clear basis for assessment.

  • Three legs, argued separately — scientific validity, analytical performance and clinical performance, each with its own evidence and its own conclusion
  • A scientific validity report that stands alone, because for many assays this leg rests on literature rather than on your own data
  • Plan before report — the performance evaluation plan sets the intended purpose, the analyte-condition link and the acceptance criteria
  • A documented literature route where scientific validity is established from published evidence, with a reproducible protocol, search and appraisal
  • PMPF linked from the start, so the gaps the report leaves are the gaps the follow-up plan closes
What performance evaluation covers What is included and what is excluded

Performance evaluation plan and reportIncluded

Scientific validity reportIncluded

Analytical and clinical performance sectionsIncluded

PMPF plan linkageIncluded

Notified Body assessmentTheir role

Intended purpose → plan → evidence → argued → report

Included with every performance evaluation
  • Three legs argued separately
  • Scientific validity documented
  • Acceptance criteria set in the plan
  • Literature route reproducible
  • PMPF gaps identified
Quoted per deviceOn class, analyte and evidence volume
Plan and reportQuoted together — the plan scopes the report
IVDR 2017/746 Annex XIIIWith current MDCG guidance applied
ISO 9001:2015Quality management certified · cert. H3CR9TCU20251212INDQM10N

Deliverables

Performance Evaluation Report Deliverables

Each evaluation covers one device and one intended purpose, and the link between analyte and condition defines what the evaluation must establish.

Scientific validity, established on its own The association between the analyte and the clinical condition is established from published literature, consensus guidance or your own data, and presented as a separate argument rather than assumed from the assay working.

Example from a scientific validity reportFor many assays this leg rests entirely on published evidence, and it is the leg most often left implicit. A Notified Body cannot assess an unstated assumption.

Analytical performance, against stated criteria Sensitivity, specificity, trueness, precision, linearity, limits of detection and quantitation, interference and cross-reactivity are each assessed against acceptance criteria set in the plan rather than judged afterwards.

Example from an analytical performance sectionThe assay demonstrated acceptable analytical performance.LoD 0.8 ng/mL against a criterion of ≤1.0; within-run CV 3.2% against ≤5%; no interference at the tested concentrations for eleven substances. Acceptable against what, stated.

Clinical performance, on clinical samples Diagnostic sensitivity and specificity, predictive values and likelihood ratios are reported for the intended-use population, with the reference standard named and its limitations stated.

Example from a clinical performance sectionWhere the comparator is an imperfect reference standard, saying so and quantifying the effect is stronger than presenting the numbers as though it were perfect.

A plan that sets the scope of the report The intended purpose, the analyte-condition link, the evidence sources and the acceptance criteria are agreed before the evidence is gathered.

Example from a performance evaluation planWithout a plan, acceptance criteria may be chosen after the results are known. Reviewers therefore ask to see the plan.

The samples shown are illustrative and anonymised. Hover over a sample to replay it.

Compliance and Standards

Performance Evaluation Report Regulatory and Quality Standards

Where your Notified Body has a stated position, that position takes precedence.

IVDR2017/746

In Vitro Diagnostic Regulation (Annex XIII)

The legal requirement for performance evaluation: the plan, the three legs, the report and the post-market performance follow-up.

MDCGguidance

MDCG guidance for IVDs (performance evaluation series)

The working interpretation Notified Bodies apply, including on scientific validity and on what counts as sufficient evidence for each leg.

ISO20916:2019

Clinical performance studies for IVDs (good study practice)

Where clinical performance rests on your own study using specimens from human subjects, this is the good study practice standard it is held to.

ISO9001:2015

Quality management (cert. H3CR9TCU20251212INDQM10N)

How the document is drafted, reviewed, version-controlled and released.

Responsible Use of AI

Responsible Use of AI in Regulatory Writing

Regulatory reviewers trace each decision back to its evidence and to a responsible individual. For this reason, we treat source traceability as more important than drafting speed, and every statement in a regulatory document must be traceable to its source.

How We Use AI ToolsWe use AI tools to locate source material across a document set, to check the consistency of terms, figures and cross-references between documents in a submission, and to draft highly templated sections, which a writer then verifies line by line against the source.
Where We Do Not Use AIWe do not use AI tools to produce text that enters a submission without verification, to interpret clinical or benefit-risk data, to write safety narratives, to appraise literature for a clinical evaluation, or to draft any statement an assessor would expect to trace to a named, qualified individual.
What Your AI Declaration Should IncludeYour declaration should name the tool, the stage at which it was used and the human oversight applied. Journals, funders, regulators and the ICMJE January 2026 update now expect this, and an undeclared tool found later is treated as an integrity matter.

Why We Do Not Publish an AI Accuracy Figure

Accuracy figures for AI tools are usually reported by the companies that sell them.

Pubrica therefore does not quote a self-generated accuracy figure, because it would carry the same conflict of interest. Instead, we tell you which tool was used on your project, at which stage, and what a specialist changed afterwards.

Methodology

How We Write Your Performance Evaluation Report

The intended purpose statement governs the whole evaluation. If it is written loosely, the evidence burden increases in every direction.

Step one

Intended purpose and plan

We define the analyte, the condition, the population, the setting and the clinical decision the result informs, then set the evidence sources and acceptance criteria for each of the three legs.

Step two

Scientific validity

We establish the association between analyte and condition from literature, guidance or your own data, and document the search where the route is literature.

Step three

Analytical and clinical performance

We assemble the study data and assess it against the criteria in the plan, identifying gaps rather than absorbing them.

Step four

Report and PMPF linkage

We write the report for Notified Body assessment and route any residual gaps into the post-market performance follow-up plan.

Our Experts

Our Performance Evaluation Report Writing Team

A named team of regulatory specialists stays with your project from scoping to delivery. Your project coordinator introduces each team member by name before work begins.

Regulatory medical writerAuthors the document to the applicable template and guidance

Writes the document against the governing template and regulatory guidance, keeps every statement traceable to its source data, and maintains the version history and comment log through each review round.

Responsible forDrafting and source traceability
Reviews againstICH, EU MDR/IVDR or FDA guidance, as applicable
OutputSubmission-ready document
Subject matter expertClinical or scientific expert matched to your product area

Reviews the clinical and scientific content for accuracy and confirms that each conclusion is supported by the data. Each expert is matched to your therapeutic or device area.

Responsible forScientific accuracy and interpretation
Reviews againstSource data and the current literature
FieldMatched to your product
BiostatisticianStatistical review where the document reports analysed data

Checks that statistical methods, tables and conclusions are consistent with the analysis plan, and reviews how the data are presented before the document reaches regulatory review.

Responsible forStatistical accuracy
Reviews againstICH E9 and the statistical analysis plan
ToolsR, SAS, Stata
Regulatory QC reviewerIndependent quality check before delivery

Performs an independent check of the final document against source data, the template and the applicable regulatory checklist. Findings are logged and resolved before delivery.

Responsible forIndependent quality control
Reviews againstSource data and regulatory checklists
Signed off byProject lead

Packages

Performance Evaluation Report Writing Packages

Pricing depends on device class, the analyte, how much of the evidence is based on literature and whether a plan already exists.

Full PER

Performance evaluation plan and report

For IVD manufacturers preparing or rebuilding a technical file

Quoted per projectOn class, analyte and evidence volume

Delivery By scope

  • ✓Performance evaluation plan with acceptance criteria
  • ✓Scientific validity report
  • ✓Analytical performance section
  • ✓Clinical performance section
  • ✓Documented literature search where the route is literature
  • ✓PMPF gaps identified and routed

Plan and report are quoted together because the plan is what makes the report assessable.

Deliverables Request a quote
Update

PER update and PMPF report

For devices on the market with an existing evaluation

Quoted per projectOn new evidence volume

Delivery By scope

  • ✓New literature and PMPF data incorporated
  • ✓Scientific validity reassessed where the field has moved
  • ✓Performance claims re-checked against current evidence
  • ✓Standards citations brought current
  • ✓Next update cadence documented

IVDR requires updates on a regular cycle, so we document the update cadence in the report.

Deliverables Request a quote

Send us your current performance evaluation, and we will tell you free of charge which of the three legs is least supported. In our experience, it is usually scientific validity, which reviewers often ask about first.

FAQs

Performance Evaluation Report FAQs

If your question is not answered here, ask an expert — no quote is required.

Scientific validity is the association between the analyte and the clinical condition. Analytical performance is whether the assay measures the analyte accurately. Clinical performance is whether the result is clinically useful in the intended population.

They are separated because they rest on different evidence and can fail independently. An assay can be analytically excellent and clinically useless, and a report that blends the legs hides which is which.

Yes, and for many established analytes it does. What IVDR requires is that the route is documented — a search protocol, appraisal criteria and a reproducible result rather than a reading list.

This is the leg most often left implicit because the association is considered well known. A well-known association still requires a citation.

Different regulation, different structure. A clinical evaluation report is a medical device document under MDR Annex XIV; a performance evaluation report is an IVD document under IVDR Annex XIII.

The approach is the same, with a documented search, stated criteria and evidence argued rather than asserted, but the structures are not interchangeable, and a CER template used for an IVD is readily identified.

Yes, and they belong together. The performance evaluation identifies what is not yet established; the post-market performance follow-up plan says how it will be.

When the two are written separately, the gaps identified in one are rarely the gaps addressed in the other, which is itself a finding.

Related Services

Related IVD and Clinical Evaluation Services

The PER is the IVD counterpart of the clinical evaluation report and draws on the same evidence methods.

Request a Free Review of Your Performance Evaluation Report

We will tell you free of charge which of the three legs is least supported. It is usually scientific validity, which reviewers often ask about first.

Get a free quote

Regulations

Check your project against this rule

  1. 1Your work
  2. 2Your details
  3. 3Send
What do you need?

Material you send is held under signed confidentiality, with access limited to the assigned team and encrypted transfer. It is not used to train anything and is not passed to third-party tools. Ask for the agreement before you send anything you would rather cover first.